kjeldahl nitrogen apparatus
kjeldahl nitrogen apparatus

Kjeldahl Nitrogen Analyzer

Automatic Kjeldahl Nitrogen Analyzer to analysis crude protein content in grain food feed soil meat etc
0.1-240 mg N
Analysis range
≤ 0.5%
Precision (RSD)
≥ 99.5% (± 0.5%)
Recovery rate
Share:
Product Details
Automatic kjeldahl nitrogen analyzer:
1.The method is a classical method for determining nitrogen. At present, Kjeldahl method is widely used to determine soil, food, animal husbandry, agricultural products, feed and other nitrogen compounds. 

2.When using this method to determine samples, three processes are required: sample digestion - distillation separation - titration analysis.

3.It is an analytical system developed based on the classical Kjeldahl nitrogen determination method for the automatic distillation and separation of samples and the analysis of "nitrogen element" (protein) through external related technologies.

4. Its method and manufacturing comply with the manufacturing standards of GB/T 33862-2017 Full (Semi) Automatic Kjeldahl Nitrogen Determination Instrument and relevant international standards

Secure protection system
1.Leakage protection system to prevent leakage and electric shock to ensure the safety of operators

2.Digestive tube vacancy system does not add reagent or heat to prevent reagent and steam from injuring people

3.The system does not work when the safety door is not closed, and the 5mm thick transparent safety door ensures personal safety

4.Automatic shutdown and alarm of water shortage system of steam system to prevent accidents

5.Automatic shutdown and alarm of steam boiler over temperature system
Characteristics
The embedded operating system of JK9830 automatic Kjeldahl nitrogen determination instrument with independent intellectual property rights adopts a 7-inch color touch screen, and the menu is Chinese man-machine dialogue, which is easy to operate and learn.
Automatic shutdown function, the system automatically shuts down after 60 minutes of unmanned operation, saving energy, safety and confidence.
The operation method, reagent preparation, precautions, maintenance and maintenance are placed on the screen for users to query and use.
Professional and excellent pumps, valves and imported pipeline systems fully guarantee the reliability and stability of products..
The steam system provides constant pressure steam flow with good stability and safety.
Multi functional interface can be used to connect the refrigeration system and reagent tank level sensor.
Metal (304 stainless steel) steam cooker: stable, reliable and strong compression resistance.
16M data storage capacity can store 100000 sample data for reference.
Built in protein coefficient query table for users to read, query and participate in system calculation.
JK9830 automatic nitrogen determination instrument is equipped with 99 groups of user-defined program (formula) management system.
"Nitro" type samples can be measured by time delay analysis.
Parameter
Model AK9830
Analysis range 0.1-240 mg N
Precision (RSD) ≤ 0.5%
Recovery rate (indication error) ≥ 99.5% (± 0.5%)
Sample analysis time 3-5 min/(cooling water temperature 18 ℃)
Data storage capacity 100000 groups of data
Communication interface 232/network/cooling water/reagent level
Delay analysis Reaction time 0-2 hours
Safe alkali dosing mode 0-999 seconds
Automatic shutdown time 60 minutes
Working voltage AC220V/50Hz
Heating power 2000W
Boundary dimension 500 * 460 * 710mm
Net weight 26Kg
Message
Related Products
protein tester nir machine
Analysis time:<10s
Wavelength repeatability:<0.01nm
Wavelength accuracy:<0.1nm 
NIR Feed Analyzer
raw fiber analyzer
Raw fiber analysis in grain,food,feed
Test range : 0~100%
Test samples at a batch : 6
CXC-06 Crude Fiber Analyzer
falling number analysis
For amylase activity in grains
For grains, wheat,wheat flour
Microcomputer control
FN-II Falling Number Machine
fully automatic kjeldahl analyser
Measurement range: 0.1mg~240mg nitrogen
Measurement speed: 3-8 minutes
Recovery rate: ≥ 99.5%
AK9870 Fully Automatic Kjeldahl Nitrogen Analyzer
Gluten tester
Agitator speed: 120r/min ± 2r/min
Head:Double
MJ-IIA Double Head Gluten Tester
soxhlet extractor
Determination range: 0.1% - 100%
Solvent cup volume: 150mL
Solvent recovery: ≥ 85%
JRZF-06 Full automatic Soxhlet fat analyzer
Amylose Tester
Test parameters:Amylose content
Wavelength: 650nm
Error:0.001
DPCZ-II Amylose content analyzer
whiteness tester
Repeatability:≤0.1
Indicating value drift:≤0.1
Zero point drift:≤0.1
WSB-V Flour Whiteness Meter
First tier manufacturer of precise equipment for  Laboratories
Aoda Instrument Equipment is the first tier manufacturer of precise equipment for  Laboratories, Scientific research institutions and colleges, Medical,Environmental protection agencies,Petrochemical industry etc.
Reliabe And Performance
In-Time Manufacturing
Reliabe And Performance
Reliabe And Performance
Reliabe And Performance
Request A Quote
We will contact you as soon as possible .
*