Cialan Automatic Kjeldahl Analyzer for nitrogen analysis in food

CIALAN is a premier manufacturer of Kjeldahl analyzer in China, we provide kjeldahl analyzer, protein analyzer, kjeldahl distiller and professional after-service. Please send us inquiry freely.
0.1-240 mg N
Analysis range
≤ 0.5%
Precision (RSD)
7-inch LCD
Touch Screen
Share:
Product Details
 Kjeldahl method is a classic method for nitrogen determination. At present, the Kjeldahl method is commonly used for the determination of soil, food, animal husbandry, agricultural products, feed and other nitrogen-containing compounds. Separation - three processes of titration analysis.
The CJK9830/9830A automatic Kjeldahl nitrogen analyzer is an analysis system developed based on the classic Kjeldahl method for automatic distillation, automatic separation and analysis of "nitrogen" (protein) through external related technologies. Its methods and manufacturing conform to relevant international standards.

Advantages
Intelligent operation. Safe Energy efficient.Three levels of rights management.
Intuitive operating system: Colorful touch screen, Chinese and English conversion.
Versatile range of applications: Measurement of nitrogen and protein content.
High-quality manufacturing materials: Steam and cooling system are made of 304 stainless steel.
Characteristics
The operating system adopts a 7-inch(10-inch for CJK-9830A) color touch screen, and the man-machine dialogue is simple and easy to operate and learn. The system automatically shuts down after 60 minutes of unattended operation, saving energy, safety, and peace of mind.
The three-level user management meets the relevant certification requirements, and the operation traceability query system. The titration volume input automatically calculates the analysis results and stores, displays, inquires, and prints, and has some functions of the fully automatic product.
Operation method, reagent preparation, precautions, maintenance screen query to facilitate users' daily application. The instrument has a built-in protein coefficient query table for users to access, query and participate in system calculation when analyzing proteins.
16M data storage capacity can store 100,000 sample data for users to consult, PID-regulated steam system can provide stable steam flow to ensure effective sample separation. Measurement of "nitro"-like samples by time-lapse analysis. 99 groups of user-defined programs (recipes) management system
The multi-function interface can be connected to the refrigeration system and the liquid level sensor of the reagent tank. Metal material (304 stainless steel) steam boiler has stable performance, reliability and strong pressure resistance.
Professional, high-quality pumps, valves, and imported pipelines fully guarantee product reliability and stability. Leakage protection system ensures operator safety. Absence of digestive tract protection system to prevent reagents and steam from hurting people.
5mm thick transparent safety door and safety door alarm system to ensure personal safety. Steam system water shortage alarm prompt, shutdown to prevent accidents. Steam boiler over-temperature alarm, shutdown to prevent accidents.
Safe alkali addition mode can reduce the strong reaction of alkali addition process and prevent pipe bursting phenomenon.
Sample over-temperature alarm and shutdown to prevent sample temperature rise and affect analysis data.(CJK9830A)
Steam overpressure alarm and shutdown to prevent accidents.(CJK9830A). Automatic discharge of digestive waste liquid reduces labor intensity of staff.(CJK9830A). 5.7CM automatic paper cutting thermal printer.(CJK9830A)
Shut down and automatically clean the alkali pipeline to prevent the alkali pipeline from being blocked and ensure the accuracy of liquid supply.(CJK9830A)
Steam flow 50%--100% can be adjusted arbitrarily for different concentration samples.(CJK9830A). Cooling water flow monitoring prevents insufficient water flow causing sample loss and affecting analysis results.(CJK9830A)
Parameter
Model CJK9830 CJK9830A
Analysis range 0.1-240 mg N 0.1-240 mg N
Precision (RSD) ≤ 0.5% ≤ 0.5%
Recovery rate (indication error) 99-101% (±1%) 99-101% (±1%)
Sample analysis time 3-5 min/(cooling water temperature 18 ℃) 3-5 min/(cooling water temperature 18 ℃)
Titrate concentration input method Manual input Manual input
Touch screen 7-inch color LCD touch screen 10-inch color LCD touch screen
Printer / 5.7CM thermal automatic paper cutter printer
Data storage capacity 100000 sets of data 100000 sets of data
Communication interface Refrigeration circulator Refrigeration circulator
Digestive tube discharge mode / Manual / automatic discharge (5-99S)
Steam flow regulation / 50%--100%
Delay analysis Response time 0-2 hours Response time 0-2 hours
Safe alkali dosing mode 0-999 seconds 0-999 seconds
Automatic shutdown time 60 minutes 60 minutes
Working voltage AC220V/50Hz AC220V/50Hz
Heating power 2000W 2000W
Boundary dimension 500 * 460 * 710mm 500 * 460 * 710mm
Net weight 30Kg 30Kg
Product configuration list
Reagent bucket 3. Waste Tank 1. Reagent tubes 4. Cooling water pipe 2. Power cord 1 M19 Tool 1. 57CM printing paper 8 (CJK9830A)


Application field




Supporting machine for Kjeldahl nitrogen distillation



















 
Message
Related Products
nir spectrometer
Analysis time:<10s
Wavelength repeatability:<0.01nm
Wavelength accuracy:<0.1nm 
NIR spectrometer for grain food feed analysis
raw fiber analyzer
Raw fiber analysis in grain,food,feed
Test range : 0~100%
Test samples at a batch : 6
CXC-06 Crude Fiber Analyzer
falling number analysis
For amylase activity in grains
For grains, wheat,wheat flour
Microcomputer control
FN-II Falling Number Machine
Kjeldahl Protein Analyzer
Measurement range: 0.1-240 mg N
Titration speed:  0.13—0.7ml/S
Titration accuracy:0.75μL/step
Cialan Fully Automatic Kjeldahl Nitrogen Analyzer For Protein Analysis
Gluten tester
Agitator speed: 120r/min ± 2r/min
Head:Double
MJ-IIA Double Head Gluten Tester
soxhlet extractor
Determination range: 0.1% - 100%
Solvent cup volume: 150mL
Solvent recovery: ≥ 85%
JRZF-06 Full automatic Soxhlet fat analyzer
Amylose Tester
Test parameters:Amylose content
Wavelength: 650nm
Error:0.001
DPCZ-II Amylose content analyzer
whiteness tester
Repeatability:≤0.1
Indicating value drift:≤0.1
Zero point drift:≤0.1
WSB-V Flour Whiteness Meter
First tier manufacturer of precise equipment for  Laboratories
Aoda Instrument Equipment is the first tier manufacturer of precise equipment for  Laboratories, Scientific research institutions and colleges, Medical,Environmental protection agencies,Petrochemical industry etc.
Reliabe And Performance
In-Time Manufacturing
Reliabe And Performance
Reliabe And Performance
Reliabe And Performance
Request A Quote
We will contact you as soon as possible .
*