fat analyzer soxhlet extraction apparatus
fat analyzer soxhlet extraction apparatus

JRZF-06 Full automatic Soxhlet fat analyzer

Soxhlet fat analyzer do crude fat content test in grain,feed,food,milk,soil etc
0.1% - 100%
Determination range
150mL
Solvent cup volume
≥ 85%
Solvent recovery
Share:
Product Details
Soxhlet extraction fat analyzer
1.JRZF-06 full-automatic fat analyzer is based on Soxhlet extraction principle and uses gravimetric method to determine the fat content in grains, cereals and foods. 

2.Conform to GB 5009.6-2016 Determination of Fat in Food; GB/T 6433-2006 Determination of Crude Fat in Feeds; SN/T 0800.2-1999 Inspection Method for Crude Fat of Imported and Exported Grain and Feed

3.The product is designed for full-automatic one key operation, which is easy to operate, stable in performance and high in precision.

4. It has many automatic extraction modes, such as Soxhlet extraction, hot extraction, Soxhlet hot extraction, continuous flow and standard hot extraction
Characteristics
The control system is composed of 7-inch LCD true color touch screen+stable PLC, which is reliable, stable and easy to operate.
Built in 6 kinds of extraction methods, which can be switched at any time and selected at will. (Soxhlet extraction, hot extraction, Soxhlet hot extraction, continuous flow, inching flow and standard hot extraction).
One key operating system: complete the pressing, heating, soaking, extraction, reflux and opening and closing processes. It is unnecessary to lift the filter paper cup and open and close the valve manually midway.
Fully automatic lifting and pressing system with high degree of automation, reliability and instant noodles.
Solenoid valve inching opening and closing, timing opening and closing, manual opening and closing wait for multiple modes, and soaking extraction mode has high efficiency.
The automatic lifting function of the extraction filter paper cup holder ensures that the sample is immersed in organic solvent at the same time, which helps to improve the consistency of the sample determination results.
The fat tester is heated by an integrated metal bath, with fast and uniform temperature rise.
The organic solvent heating system * has the temperature programmed function, which has the common functions of temperature fixing, timing and timing.
The automatic fat analyzer can adjust the heating temperature at will according to the different boiling points of reagents and ambient temperatures.
Applicable to all kinds of organic solvents, including petroleum ether, acetone, dichloromethane, n-hexane, alcohols, imitations and benzene.
Intelligent temperature control is adopted for cooling water inlet and outlet, with obvious energy-saving effect.
Petroleum ether leakage alarm. When the working environment is dangerous due to petroleum ether leakage, the alarm system starts and stops heating.
Parameter
Model JRZF-06
Determination range 0.1% - 100%
Temperature control range RT+5 ℃ - 280 ℃
Temperature control accuracy ± 1 ℃
Quantity of measured samples 6 pieces/time
Determine the sample weight 0.5g~15g
Solvent cup volume 150mL
Solvent recovery ≥ 85%
System control mode PLC+7-inch true color touch screen, Chinese menu interface
Heating power 1500W
Voltage 220V ± 10%/50Hz
Automatic recovery cock electromagnetic automatic opening and closing
Automatic lifting of extractor lifting system
Message
Related Products
protein tester nir machine
Analysis time:<10s
Wavelength repeatability:<0.01nm
Wavelength accuracy:<0.1nm 
NIR Feed Analyzer
raw fiber analyzer
Raw fiber analysis in grain,food,feed
Test range : 0~100%
Test samples at a batch : 6
CXC-06 Crude Fiber Analyzer
falling number analysis
For amylase activity in grains
For grains, wheat,wheat flour
Microcomputer control
FN-II Falling Number Machine
fully automatic kjeldahl analyser
Measurement range: 0.1mg~240mg nitrogen
Measurement speed: 3-8 minutes
Recovery rate: ≥ 99.5%
AK9870 Fully Automatic Kjeldahl Nitrogen Analyzer
Gluten tester
Agitator speed: 120r/min ± 2r/min
Head:Double
MJ-IIA Double Head Gluten Tester
soxhlet extractor
Determination range: 0.1% - 100%
Solvent cup volume: 150mL
Solvent recovery: ≥ 85%
JRZF-06 Full automatic Soxhlet fat analyzer
Amylose Tester
Test parameters:Amylose content
Wavelength: 650nm
Error:0.001
DPCZ-II Amylose content analyzer
whiteness tester
Repeatability:≤0.1
Indicating value drift:≤0.1
Zero point drift:≤0.1
WSB-V Flour Whiteness Meter
First tier manufacturer of precise equipment for  Laboratories
Aoda Instrument Equipment is the first tier manufacturer of precise equipment for  Laboratories, Scientific research institutions and colleges, Medical,Environmental protection agencies,Petrochemical industry etc.
Reliabe And Performance
In-Time Manufacturing
Reliabe And Performance
Reliabe And Performance
Reliabe And Performance
Request A Quote
We will contact you as soon as possible .
*