aa spectrometry
aa spectrometry

4530F Atomic Absorption Spectrophotometer(Graphite Furnace)

Atomic Absorption Spectrophotometer 4530F comes with flame system and graphite furnace system.
190 – 900nm
Wavelength Range
0.1nm,0.2nm,0.4nm,1.0nm,2.0nm
Bandwidth
±0.15nm
Wavelength Accuracy
Share:
Product Details
AAS 4530F Complete automatic controlling system:With the help of the software, the following can be easily achieved:
1.Selection of the element lamp
2.Up-down-front-rear adjustment of the lifter
3.Adjustment of the optical energy
4.Selection of the slit
5.Determination of wavelength scanning and peak searching
6.Selection of the atomizer
7.Setting of the background deduction method 
8.Controlling of the gas flow
9.Automatic flaming and flaming out 
10.Setting of the graphite furnace testing method
Characteristics
Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).
.Integrated floated optical platform design can obviously improve the optical system shock resistance and can keep stable though use the optical signal for a long term.
Eight light stands can be changed automatically and preheat the eight element lights meantime as well as optimize the working condition of the hollow cathode lamp.
Position adjusting: the best height of the flame burner and can automatically set the front and rear positions.
Fully automated wavelength scanning and peak searching.Deuterium lamp and self-absorption background regulation.
Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flame out.
Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function.
Measuring method: flame absorption method and emission method.Result printing: parameter printing, data result printing and diagram printing.
Parameter
Model:AA-4530F
Optical System
Wavelength range 190-900nm
Spectral bandwidth Can automatically change between 0.1nm, 0.2nm, 0.4nm, 1.0nm and 2.0nm
 Accuracy of the wavelength ±0.15nm
Receptivity of the wavelengt  ≤0.04nm
 Base line stability ≤0.002A/30min (Cu)
Characteristic viscosity 0.02μg/ml/1% (Cu)
Checking limit 0.004μg/ml (Cu)
Preciseness 0.5%
Grating 1800 lines/mm
 In flamer All-metal titanium burner
Atomizer Effective glass atomizer
 Lamp stand Eight lamps
Flame Method
Acetylene air burner 100mm
Nitrous oxide acetylene flame head 50mm
 Ignition dynamic baseline drift ≤0.006A/30min
 (Cu) Characteristic viscosity ≤0.025μg/ml/1%
Related standard deviation of the accuracy ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)
Graphite furnace
The highest temperature 3000℃
The largest temperature rising speed ≥2000℃/S
Characteristic quantity Cd≤0.5×10-12g  Cu≤0.5×10-11g
Accuracy Cu≤3%  Cd≤3%
 Safety system Over current protection
Message
Related Products
First tier manufacturer of precise equipment for  Laboratories
Aoda Instrument Equipment is the first tier manufacturer of precise equipment for  Laboratories, Scientific research institutions and colleges, Medical,Environmental protection agencies,Petrochemical industry etc.
Reliabe And Performance
In-Time Manufacturing
Reliabe And Performance
Reliabe And Performance
Reliabe And Performance
Request A Quote
We will contact you as soon as possible .
*