AA-7020 Atomic Absorption Spectrophotometer For Quantitative Analysis — Cialan

Cialan is the first tier manufacturer and supplier of AAS in China, we provide aas spectroscopy, aas instrument, atomic absorption machine and professional after-service.
190 – 900nm
Wavelength Range
0.1, 0.2, 0.4, 1.0 ,2.0nm
Bandwidth
±0.1nm
Wavelength Accuracy
Share:
Product Details
Atomic absorption spectrometer can be used in the fields of metallurgy, petrochemical, geology, medical science, environmental protection, scientific research, agriculture, disease control, food safety, material science, and quality inspection among others. 
Characteristics
First domestic manufacturer to use an 1800 lines/mm diffraction grating, which increases resolution and energy efficiency.
Optimized lamp power supply technology to prolong lifetime of element lamps.
Safe and reliable control alarming devices to ensure over-current protection for hollow cathode lamps.
Automatic wavelength positioning, automatic slit switch and automatic optimization of lamp current and gain. All of these operations can be completed within 40 seconds.
Auxiliary gas, such as oxygen, can be used in the internal gas path of the graphite furnace to sufficiently remove organic components of the sample during the ashing treatment phase in order to reduce interference and increase analysis accuracy.
Automatically find the optimal flame height for best analysis condition.
Flame ignition is controlled with a combination of a float inside the liquid trap and an electromagnetic valve to avoid acetylene leakage due to lack of water in the liquid trap. This increases operation safety.
Parameter
Model:AA-7020
Optical System
Wavelength range 190-900nm
Spectral bandwidth Automatic switching between 5 levels: 0.1, 0.2, 0.4, 1.0, 2.0 nm
Mono-chromator C-T Grating Mono-chromator
Wavelength accuracy ±0.1 nm
Wavelength repeatability  ≤0.05 nm
Grating 1800 lines/mm
Blaze wavelength 250 nm
Baseline stability   ≤±0.003A/30 min (Static)
  ≤±0.002A/30 min (Dynamic)
Resolution Better than 0.1nm
Flame Method
Benchmark Con*centration of Cu ≤0.02 μg/ml
Detection Limit ≤0.003 μg/ml
Precision RSD ≤0.6%
Burner Interchangeable full titanium burner of 50 mm and 100 mm
Position Adjustment Adjustable height and angle. Flame to hydride can be switched in less than 1 minute.



Applications




Supporting instrument









Message
Related Products
aa spectrophotometer price
Wavelength range:190 – 900nm
Spectral bandwidth:0.1nm,0.2nm,0.4nm,1.0nm,2.0nm
Graphite atomizer
Graphite Furnace Atomic Absorption Spectrophotometer For Trace Analysis — Cialan
atomic absorption spectrometer
Wavelength range:190 – 900nm
Spectral bandwidth:0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Single beam
 
AA320N Flame Atomic Absorption Spectrophotometer For Metal Analysis — Cialan
zeeman atomic absorption spectroscopy
Wavelength range:190 – 900nm
Spectral bandwidth:0.1, 0.2, 0.4, 1.0 ,2.0nm
Zeeman background
 
Zeeman Background Atomic Absorption Spectrophotometer — Cialan
cost of atomic absorption spectrophotometer
Wavelength range:190 – 900nm
Spectral bandwidth:0.1, 0.2, 0.4, 1.0 ,2.0nm
Wavelength Accuracy:±0.1nm
 
AA-7020 Atomic Absorption Spectrophotometer For Quantitative Analysis — Cialan
First tier manufacturer of precise equipment for  Laboratories
Aoda Instrument Equipment is the first tier manufacturer of precise equipment for  Laboratories, Scientific research institutions and colleges, Medical,Environmental protection agencies,Petrochemical industry etc.
Reliabe And Performance
In-Time Manufacturing
Reliabe And Performance
Reliabe And Performance
Reliabe And Performance
Request A Quote
We will contact you as soon as possible .
*